Skip to main content

Loss Distribution Methodology with a Sense Of Emission Dispatch


Volume 6 Issue 1 December - February 2018
Research Paper
Srilatha Dande*, Sivanagaraju Sirigiri**
* Research Scholar, JNT University, Kakinada, Andhra Pradesh, India.
** Professor, Department of Electrical and Electronics Engineering, University College of Engineering, JNT University, Kakinada, Andhra Pradesh, India
Dande, S., and Sirigiri, S. (2018). Loss Distribution Methodology With A Sense Of Emission Dispatch. i-manager’s Journal on Circuits and Systems, 6(1), 1-9. https://doi.org/10.26634/jcir.6.1.14037
Abstract
In this paper, a novel methodology with load flow implementation has been presented to remove extra burden on slack bus in emission aspect. Using this methodology, the effect of nature of power plant (Thermal/Gas) has been analyzed on the system objectives. Optimal Unfied Power Flow Controller (OUPFC) is incorporated in the system for the power flow control. As this methodology works independent of the size and nature of the system, it can be applicable for any type of system. The complete methodology has been tested on IEEE-14 bus test system with supporting numerical and graphical results.

Comments

Popular posts from this blog

An improved Multilevel Inverter with Lesser Number of Switches for An Induction Motor Drive

Volume 2 Issue 1 December - February 2014 Research Paper An improved Multilevel Inverter with Lesser Number of Switches for An Induction Motor Drive Ayyappa Srinivasan M G*, Nirmal Singh** *Assistant Professor, Department of Electrical and Electronics Engineering, St.Mother Theresa Engineering College, Tuticorin, India. **Professor, Department of Electronics and Communication Engineering, V.V. College of Engineering, Tisayanvilai, India Srinivasan, A.M.G and Singh, N. N (2014). An Improved Multilevel Inverter With Lesser Number of Switches for an Induction Motor Drive.  i-manager’s Journal on Circuits and Systems , 2(1), 7-14.  https://doi.org/10.26634/jcir.2.1.2783 Abstract An improved three level inverter scheme, with less number of switches, having the features of common mode voltage elimination, DC link capacitor voltage balancing, and minimization and equalization of voltage stress across the switches, for an open end winding induction motor drive, h...

Reduced Wirelength-Based Low Power Performance of Multibit Flip-Flop

Volume 1 Issue 4 September - November 2013 Research Paper Reduced Wirelength-Based Low Power Performance of Multibit Flip-Flop M.Karthick*, S. Vijayakumar** *PG Scholar, Department of Electronics and Communication Engineering, Paavai Engineering College, Namakkal, India. **Associate Professor, Department of Electronics and Communication Engineering, Paavai Engineering College, Namakkal, India. Karthick, M. and Vijayakumar, S. (2013). Reduced Wire length-Based Low Power Performance Of Multibit Flip-Flop.  i-manager’s Journal on Circuits and Systems , 1(4), 22-26.  https://doi.org/10.26634/jcir.1.4.2593 Abstract Power reduction is a main parameter to design VLSI circuits. In this paper, to design a number of D-flip flop performing at the same time, the given clock signal is reduced using multi bit flip-flop. The multi bit flip flop is mainly used to improve the clock power for the given common clock signal and to reduce the switching power. This method is p...

Fuzzy Logiccontrol Of Differential Protection For Large Power Transformer

Volume 1 Issue 1 December - February 2013 Research Paper Fuzzy Logiccontrol Of Differential Protection For Large Power Transformer S.Padmini*, Subransu Sekhar Dash**, S. Chandrasekhar***, Priyanka Vedula**** * Assistant Professor, SRM University. ** Professor and Head, Department of EEE, SRM University, Shruti. ***-**** B. Tech Student, SRM University. Padmini, S., Dash, S. S., Chandrasekhar, S. and Vedula, P. (2013). Fuzzy Logiccontrol Of Differential Protection For Large Power Transformer.  i-manager’s Journal on Circuits and Systems , 1(1), 10-15.  https://doi.org/10.26634/jcir.1.1.2194 Abstract Advances Differential prot ecti on system is us e d t o protect most of the power transformers in power systems. The protection system is based on the differential currents/voltages of the primary an d secondary of the transformers under fault conditions and under normal operating conditions. The inrus currents or the magnetizing currents are generated in the...