Skip to main content

A Novel Fault Detection Method for EHV Transmission Line Networks


Volume 2 Issue 2 March - May 2014
Research Paper
Ch. Durga Prasad*
Department of EEE, S.R.K.R.Engineering College, Bhimavaram, Andhra Pradesh
Prasad, Ch. D. (2014). A Novel Fault Detection Method for EHV Transmission Line Networks. i-manager’s Journal on Circuits and Systems , 2(2), 18-25. https://doi.org/10.26634/jcir.2.2.2975
Abstract
This paper proposes an effective Fault Detection Technique in distance relaying using discrete current samples. The original signal under fault consists of two parts namely, normal and disturbance part. The fault detection is easily achieved as the disturbance part of the signal produces an irregular shape compared to the shape produced from the normal part of the signal. By selecting suitable threshold value, the starting point of irregular part can be found. The proposed algorithm is so effective and easy when compared to other algorithms. Results are carried out in MATLAB/SIMULINK software.

Comments

Popular posts from this blog

An improved Multilevel Inverter with Lesser Number of Switches for An Induction Motor Drive

Volume 2 Issue 1 December - February 2014 Research Paper An improved Multilevel Inverter with Lesser Number of Switches for An Induction Motor Drive Ayyappa Srinivasan M G*, Nirmal Singh** *Assistant Professor, Department of Electrical and Electronics Engineering, St.Mother Theresa Engineering College, Tuticorin, India. **Professor, Department of Electronics and Communication Engineering, V.V. College of Engineering, Tisayanvilai, India Srinivasan, A.M.G and Singh, N. N (2014). An Improved Multilevel Inverter With Lesser Number of Switches for an Induction Motor Drive.  i-manager’s Journal on Circuits and Systems , 2(1), 7-14.  https://doi.org/10.26634/jcir.2.1.2783 Abstract An improved three level inverter scheme, with less number of switches, having the features of common mode voltage elimination, DC link capacitor voltage balancing, and minimization and equalization of voltage stress across the switches, for an open end winding induction motor drive, h...

Reduced Wirelength-Based Low Power Performance of Multibit Flip-Flop

Volume 1 Issue 4 September - November 2013 Research Paper Reduced Wirelength-Based Low Power Performance of Multibit Flip-Flop M.Karthick*, S. Vijayakumar** *PG Scholar, Department of Electronics and Communication Engineering, Paavai Engineering College, Namakkal, India. **Associate Professor, Department of Electronics and Communication Engineering, Paavai Engineering College, Namakkal, India. Karthick, M. and Vijayakumar, S. (2013). Reduced Wire length-Based Low Power Performance Of Multibit Flip-Flop.  i-manager’s Journal on Circuits and Systems , 1(4), 22-26.  https://doi.org/10.26634/jcir.1.4.2593 Abstract Power reduction is a main parameter to design VLSI circuits. In this paper, to design a number of D-flip flop performing at the same time, the given clock signal is reduced using multi bit flip-flop. The multi bit flip flop is mainly used to improve the clock power for the given common clock signal and to reduce the switching power. This method is p...

Fuzzy Logiccontrol Of Differential Protection For Large Power Transformer

Volume 1 Issue 1 December - February 2013 Research Paper Fuzzy Logiccontrol Of Differential Protection For Large Power Transformer S.Padmini*, Subransu Sekhar Dash**, S. Chandrasekhar***, Priyanka Vedula**** * Assistant Professor, SRM University. ** Professor and Head, Department of EEE, SRM University, Shruti. ***-**** B. Tech Student, SRM University. Padmini, S., Dash, S. S., Chandrasekhar, S. and Vedula, P. (2013). Fuzzy Logiccontrol Of Differential Protection For Large Power Transformer.  i-manager’s Journal on Circuits and Systems , 1(1), 10-15.  https://doi.org/10.26634/jcir.1.1.2194 Abstract Advances Differential prot ecti on system is us e d t o protect most of the power transformers in power systems. The protection system is based on the differential currents/voltages of the primary an d secondary of the transformers under fault conditions and under normal operating conditions. The inrus currents or the magnetizing currents are generated in the...