Skip to main content

High Performance Interleaved Bi-Directional Dc-Dc Converter With Zero Voltage Switching


Research Paper
D. suganya*, R. Selvaraj**
* PG Scholar, Roever Engineering College, Anna University, Chennai, Tamilnadu.
** PhD Research Scholar, NIT, Trichy.
Suganya, D., and Selvaraj, R. (2014). High Performance Interleaved Bi-Directional Dc-Dc Converter With Zero Voltage Switching. i-manager’s Journal on Circuits and Systems, 2(3), 12-16. https://doi.org/10.26634/jcir.2.3.3153
Abstract
A high performance interleaved bi-directional dc–dc converter with zero voltage switching can convert low-voltage reversible power sources to a high voltage dc bus individually or simultaneously by the phase-shift control, and also can step down the high-voltage dc bus to charge the power sources. The reversible power sources can charge each other. The circuit is designed as half-bridge circuit. The inductors in the proposed converter are designed to operate in synchronous conduction mode for achieving turn-on zero-voltage-switching (ZVS) of all switches. The effectiveness of the designed circuit topology, ZVS properties and the goal of high-performance conversion can be obtained.

Comments

Popular posts from this blog

Continuous Overvoltage Characteristics of Surge Protected Power Strips

Volume 5 Issue 4 September - November 2017 Research Paper Continuous Overvoltage Characteristics of Surge Protected Power Strips Cengiz Polat* Assistant Professor, Department of Electrical and Electronics Engineering, Istanbul University, Istanbul, Turkey. Uzunoglu, C. P. (2017). Continuous Over Voltage Characteristics of Surge Protected Power Strips.  i-manager’s Journal on Circuits and Systems,  5(4), 1-7.  https://doi.org/10.26634/jcir.5.4.13938 Abstract Increasing applications of constantly developing electronic devices require delicate voltage and current protection. Although the electrical network is monitored continuously, undesired over currents and over voltages may occur on the distribution system due to failures. Most of the electronic switch gear is connected via surge protected power strips in indoor applications, where current protection is vital. Surge protected power strips are usually manufactured based on Metal Oxide Varistors (MOVs) ...

Reduced Wirelength-Based Low Power Performance of Multibit Flip-Flop

Volume 1 Issue 4 September - November 2013 Research Paper Reduced Wirelength-Based Low Power Performance of Multibit Flip-Flop M.Karthick*, S. Vijayakumar** *PG Scholar, Department of Electronics and Communication Engineering, Paavai Engineering College, Namakkal, India. **Associate Professor, Department of Electronics and Communication Engineering, Paavai Engineering College, Namakkal, India. Karthick, M. and Vijayakumar, S. (2013). Reduced Wire length-Based Low Power Performance Of Multibit Flip-Flop.  i-manager’s Journal on Circuits and Systems , 1(4), 22-26.  https://doi.org/10.26634/jcir.1.4.2593 Abstract Power reduction is a main parameter to design VLSI circuits. In this paper, to design a number of D-flip flop performing at the same time, the given clock signal is reduced using multi bit flip-flop. The multi bit flip flop is mainly used to improve the clock power for the given common clock signal and to reduce the switching power. This method is p...

A Review on Control strategies for LFC in Deregulated Scenario

Volume 1 Issue 1 December - February 2013 Review Paper A Review on Control strategies for LFC in Deregulated Scenario T. Anilkumar*, N. Venkata ramana** * Associate Professor, EEE Department, ACE Engineering College, Ghatkesar, Hyderabad, AP, India. ** Professor and Head of Deportment, EEE Department, JNTU Mantini, AP, India. Kumar, T. A., and Ramana, N., (2013). A Review On Control Strategies For LFC In Deregulated Scenario.  i-manager’s Journal on Circuits and Systems , 1(1), 27-36.  https://doi.org/10.26634/jcir.1.1.2197 Abstract In power system studies, Load frequency control is an important issue to supply sufficient and reliable electric power with good quality. The main objective of LFC is to maintain load frequency and tie-line power flow within permissible limits by adjusting megawatt output of LFC generators, so as to accommodate fluctuating load demands. This paper presents a brief review of different control techniques to researchers on design...