Automatic Changeover of Wind-Solar System with New Rectifier Topology


Volume 2 Issue 2 March - May 2014
Research Paper
Kingston Roosevelt G.*
M.E Student, Electrical and Electronics Engineering (EEE), National College of Engineering, Tirunelveli.
Roosevelt, K. (2014). Automatic Changeover of Wind-Solar System with New Rectifier Topology. i-manager’s Journal on Circuits and Systems, 2(2), 10-17. https://doi.org/10.26634/jcir.2.2.2974
Abstract
This paper presents a new system configuration of the front-end rectifier stage for a hybrid wind/photovoltaic energy system. This configuration allows the two sources to supply the load separately or simultaneously depending on the availability of the energy sources. The inherent nature of this Cuk-SEPIC fused converter, is that, additional input filters are not necessary to filter out high frequency harmonics. Harmonic content is detrimental for the generator lifespan, heating issues, and efficiency. The fused multi input rectifier stage also allows Maximum Power Point Tracking (MPPT) to be used to extract maximum power from the wind and sun when it is available. An adaptive MPPT algorithm will be used for the wind system and a standard perturb and observe method will be used for the PV system. Operational analysis of the proposed system will be discussed in this paper. Simulation results are given to highlight the merits of the proposed circuit.

Comments

Popular posts from this blog

An improved Multilevel Inverter with Lesser Number of Switches for An Induction Motor Drive

Volume 2 Issue 1 December - February 2014 Research Paper An improved Multilevel Inverter with Lesser Number of Switches for An Induction Motor Drive Ayyappa Srinivasan M G*, Nirmal Singh** *Assistant Professor, Department of Electrical and Electronics Engineering, St.Mother Theresa Engineering College, Tuticorin, India. **Professor, Department of Electronics and Communication Engineering, V.V. College of Engineering, Tisayanvilai, India Srinivasan, A.M.G and Singh, N. N (2014). An Improved Multilevel Inverter With Lesser Number of Switches for an Induction Motor Drive.  i-manager’s Journal on Circuits and Systems , 2(1), 7-14.  https://doi.org/10.26634/jcir.2.1.2783 Abstract An improved three level inverter scheme, with less number of switches, having the features of common mode voltage elimination, DC link capacitor voltage balancing, and minimization and equalization of voltage stress across the switches, for an open end winding induction motor drive, h...

Reduced Wirelength-Based Low Power Performance of Multibit Flip-Flop

Volume 1 Issue 4 September - November 2013 Research Paper Reduced Wirelength-Based Low Power Performance of Multibit Flip-Flop M.Karthick*, S. Vijayakumar** *PG Scholar, Department of Electronics and Communication Engineering, Paavai Engineering College, Namakkal, India. **Associate Professor, Department of Electronics and Communication Engineering, Paavai Engineering College, Namakkal, India. Karthick, M. and Vijayakumar, S. (2013). Reduced Wire length-Based Low Power Performance Of Multibit Flip-Flop.  i-manager’s Journal on Circuits and Systems , 1(4), 22-26.  https://doi.org/10.26634/jcir.1.4.2593 Abstract Power reduction is a main parameter to design VLSI circuits. In this paper, to design a number of D-flip flop performing at the same time, the given clock signal is reduced using multi bit flip-flop. The multi bit flip flop is mainly used to improve the clock power for the given common clock signal and to reduce the switching power. This method is p...

Fuzzy Logiccontrol Of Differential Protection For Large Power Transformer

Volume 1 Issue 1 December - February 2013 Research Paper Fuzzy Logiccontrol Of Differential Protection For Large Power Transformer S.Padmini*, Subransu Sekhar Dash**, S. Chandrasekhar***, Priyanka Vedula**** * Assistant Professor, SRM University. ** Professor and Head, Department of EEE, SRM University, Shruti. ***-**** B. Tech Student, SRM University. Padmini, S., Dash, S. S., Chandrasekhar, S. and Vedula, P. (2013). Fuzzy Logiccontrol Of Differential Protection For Large Power Transformer.  i-manager’s Journal on Circuits and Systems , 1(1), 10-15.  https://doi.org/10.26634/jcir.1.1.2194 Abstract Advances Differential prot ecti on system is us e d t o protect most of the power transformers in power systems. The protection system is based on the differential currents/voltages of the primary an d secondary of the transformers under fault conditions and under normal operating conditions. The inrus currents or the magnetizing currents are generated in the...